Pressurestat, level probe and thermostats
Bezzera's manual says: if the machine is malfunctioning, do not try to repair it yourself; call technical assistance. Every BZ10 carries an anti-tamper seal that cannot survive opening the case, and Bezzera grants no warranty on a machine whose seal is removed or damaged (12 months from the invoice). Treat this as technician work.
- Pressurestat (7433012, 1.2 bar, 15 A): holds the boiler pressure. Owner adjustment: boiler pressure.
- Level probe (5265804) and control unit (7661007.01R): fill the boiler, stop the pump after 120 seconds if it does not fill, and cut the element when the boiler is low.
- Boiler safety thermostat (7634819.01, 130 °C): manual reset, technician only.
- Group heaters (5963182.01) with a 95 °C automatic thermostat (7634808).
- Pump cut-out (7634816, 100 °C, automatic).