Probes, safety thermostats and the brew switch
ECM's manual says any repair or change of components must be carried out by an authorised specialist dealer, using only original spare parts; otherwise ECM accepts no liability. Treat this as dealer work.
- Temperature probes: one in each boiler (P6037.1) and a sensor in the group (P7036). The II is PID-controlled; there is no pressurestat.
- Level probe: a dirty probe lets the steam boiler overfill. Clive's clean is on the next screen.
- Safety thermostats: 145 °C, listed on both boilers and the group.
- Brew microswitch: if the pump starts before the lever is fully up, or not at full lift, Clive adjusts the switch's nuts under the right side panel.
- Clock battery: if the timer stops switching it on, the manual says the board battery is flat; have it replaced at the next service.
Clean the level probe
Clive Coffee's method, for the original Synchronika; the II's probe has the same ECM number.
- Unplug, let it cool, and take the panels off.
- Pull the wire off the probe.
- Unscrew the whole probe assembly with a 19 mm spanner.
- Clean the probe with steel wool or a brush.
- Wrap the thread in PTFE tape and refit it without over-tightening. Push the probe fully down and tighten the upper nut with a 13 mm spanner.
- Purge: machine off, hot-water lever fully open over a large jug, switch on; when water flows, draw 240 to 350 ml, close, and let it refill.