Drag to turn · scroll to zoom

The display menu

The decoder and the basic settings

Everything is set with the decoder: double-press to open the menu, turn to move, press to choose and confirm. With no input for 5 seconds the menu closes. The manual's basic settings:

Change a setting

The manual's method.

  1. Double-press the decoder. The menu opens at Brew Temperature.
  2. Turn the decoder to the setting you want.
  3. Press to choose it.
  4. Turn to change the value.
  5. Press to confirm.
  6. Leave it for 5 seconds: the menu closes by itself.

Preinfusion: after choosing ON, set the active time (upper value), then the passive time (lower value); each is editable for 3 seconds. ECM's example is 4 seconds active and 6 passive. ECM recommends active preinfusion on the tank, and passive only (active at 0) on mains water.

Advanced settings, the timer, and a reset

Set Advanced User Settings to ON to show: Filter Reminder (OFF to 200 litres), Timer Enable (ON follows your schedule and ignores Eco), Clock Set, Schedule Set (two on and two off times per weekday), Tank Mode (ON = tank, the factory setting), Temperature Unit and Offset Correction (−10 to +10; factory 2 °C). Hiding them again keeps the values.

The manual's reset, for odd behaviour after changing settings:

  1. Switch off.
  2. Lift the brew lever.
  3. Press and hold the decoder.
  4. Switch on while holding it: the machine resets.
  5. Switch off and lower the lever.
  6. Switch on as normal and do the first start-up again.

ECM Synchronika II: every job