Drag to turn · scroll to zoom

The brew gauge sits at 12 bar while heating

The brew gauge sits at 12 bar while heating

Normal. The manual: as the coffee boiler heats, the expansion valve lets a little water out so the group stays at about 12 bar, then it stops. While brewing, the gauge reads 8 to 10 bar.

A valve that drips all the time, long after heat-up, is worn.

La Marzocco Linea Micra: every job