Boiler cap gasket
Change the cap's O-ring
La Pavoni does not list this as owner work: its manual leaves everything beyond cleaning and normal maintenance to a service centre. No source gives a method; these are the plain steps.
- Switch off and let the pressure out exactly as in filling the boiler.
- Unscrew the cap slowly.
- Ease the old O-ring off the cap with a pick, without scratching its seat.
- Fit the new O-ring (465204).
- Screw the cap back on clockwise, by hand.
- Heat up, and check the cap does not hiss.