Drag to turn · scroll to zoom

Brew pressure

What the gauge tells you

The gauge shows brew pressure. The highest pressure is set by the expansion valve, which on the Evo sits under the group and is adjusted from outside (Quick Mill's datasheet) with a flat screwdriver in its slotted screw (importer's manual).

Check and set it with the blind basket

The importer's method.

  1. Put the blind basket in the portafilter and lock it in.
  2. Turn the brew switch on.
  3. Read the gauge.
  4. If it is outside 9.5 to 10 bar, turn the slotted screw under the right side of the group a small amount, about a quarter turn.
  5. Read the gauge again. If it moved the wrong way, turn back past where you started.
  6. At 9.5 to 10 bar, turn the brew switch off and take the portafilter out.

Quick Mill Silvano Evo: every job