Close-up
Drag to turn · scroll to zoom
The display menu
Set the brew temperature
The importer's method. The display is in °F on US machines and °C on EU ones.
- With the machine on, press and release ▼: the display shows PrG.
- Press ▲ to show the set point.
- Change it with the arrows.
- Leave it: the display goes back to the temperature by itself after a few seconds.
The factory setting is 200 °F (about 93 °C). The importer recommends 195 to 205 °F (90 to 96 °C).
Advanced settings and the shot timer
The importer's method. Use it to switch between °F and °C.
- Switch the machine off.
- Hold both arrows and switch on; let go when the display shows F.03.
- Press ▲ to change the setting, wait for the display to revert, then press ▼ for the next one.
- Switch off and on again to save.
Shot timer: it counts while the brew switch is on and holds the final time for 5 seconds. One owner reported 2018 Evos without a timer; the original Silvano had none.